Table 7.

Diagnostic Efficacy of Tests for Evaporative and Aqueous-Deficient Dry Eye

Test Measure Normals vs. Dry Eye (Sens %/Spec %) Normals vs. EDE (Sens %/Spec %) EDE vs. ADDE (Sens %/Spec %)
Symptom questions DE >14.5 (82/36; vs. RB, SCH, TBUT); McMonnies132
DE >15; OSDI; (80/79 vs. Lissamine, Sch, Symp) (60/83, Dr. diagnosis); Johnson and Murphy133
Tear stability FBUT <10 seconds (82/86); Mengher et al.134
Tear secretion: Schirmer I, Schirmer II <5.5 mm/5 min (85/83); Khanal et al.92
Index of tear volume, PRT PRT <12 mm (56/69); Sakamoto et al.135
PRT <20 mm (86/83); Patel et al.136
Ocular surface damage RB Stain >3.5; van Bijsterveld137
    RB Stain >4 (95% vs. 96%) (63/84); Vitali et al.138
Lid (meibomian morphology) NA
Meibomian gland expression Expression grade >1.0*
Expressibility/volume/quality 86/73
Meibography EDE ≥ 3 (83.0/90.0); Arita et al.3
Confocal acinar unit density/diameter Unit density <70/mm; Kobayashi et al.139; Matsumoto et al.140 (81/8)
Long diameter <65 μm (90/81)
Short diameter <25 μm (86/96)
Meibometry NA
Interferometry NA
Evaporation rate DE <22 (51.1/89.9); Tomlinson et al.93 EDE >22.3 (61.2/90.6) EDE >27.5 (45.5/79.8)
Meibomian physicochemistry
Tear secretion: fluorometry, fluorescein clearance DE <12.9 (74.5/73.6); Tomlinson et al.93 EDE <15.1 (80.2/58.7) ADDE <9.6 (69.5/96.8)
Tear volume: fluorimetry NA
Tear meniscus height/radius/volume DE <0.25 (74.5/73.6)-R; Yokoi and Komuro124
DE <0.18 (72.8/66.6)-TMH; Farrell et al.141
DE <9.6 (93.3/66.7); Mainstone et al.142
Tear osmolarity DE >31694 (69%/92.8%); Tomlinson et al.93 EDE >315 (73%/72%); Khanal et al.118 ADDE >325 (60%/39%); Khanal et al.118
Tear dynamics/indices/evap/total flow DE >15 (NA); Tomlinson et al.93 EDE >15; Tomlinson et al.93 (na) EDE >NA (NA)
Tear dynamics/indices/evaporation/TTR DE >20 (NA); Tomlinson et al.93 EDE >20 (NA); Tomlinson et al.93 EDE >NA (NA)
Tear dynamics/indices/TFI DE <96; Xu et al.143 NA
DE <240 (64.7/60) (83%/40%); McCann et al.144

The sensitivity and specificity of tests discriminating normals from dry eye and its subtypes are reported. DE, dry eye; EDE, evaporative dry eye; ADDE, aqueous-deficient dry eye; TFI, tear function index; FBUT, fluorescein break-up time; PRT, phenol red thread; RB, rose bengal; SCH, Schirmer; TBUT, tear breakup time; TTR, tear turnover rate; SENS, sensitivity; SPEC, specificity.

*

McCann LC, et al. IOVS 2008;49:ARVO E-Abstract 1532.