Skip to main content
. 2010 Nov 9;400(4):915–929. doi: 10.1007/s00216-010-4372-6

Table 4.

Literature overview of lux strains for the detection of oxidative stress and their detection limits

Strain References Reacts on Promoter Receiving strain LOD Setup
DPD2511 [40] Peroxides katG RFM443 Culture plate
[21] 0.1 mg/l H2O2 Culture plate
[22] 0.0006% H2O2 ∼ 6 mg/l Portable sensor
[41] 0.1 mg/l bisphenol A Culture plate
[30] Optical fibre
[29] Antibody glass/gold plates
DPD2515 [21] Superoxides micF W3110 0.01 mg/l paraquat Culture plate
[29] Antibody glass/gold plates
DP1 [27] Superoxides pqi-5 RFM443 0.1 mg/l paraquat Bioreactor
[33] 2.5% ethanol, 7.8 mg/l paraquat Sol–gel wells
[42] Cell chip
PGRFM [38] Superoxides,
peroxides pgi RFM443 0.6 mg/l paraquat Culture plate
DK1 [27] Peroxides katG RFM443 10 mg/l H2O2 Bioreactor
[33] 0.15% 2-propanol, 0.8 mg/l H2O2 Sol–gel well plate
[45] 0.88 μM (0.03 mg/l) H2O2 Microfluid chip
EBSoxS [44] Superoxides soxS RFM443 Cell chip
DS1 [44] Superoxides sodA RFM443 Cell chip
ZWF [42] Cell chip
[43] Superoxides zwf RFM443 Culture plate
FPR [42] Cell chip
[43] Superoxides fpr RFM443 Culture plate
EBFumC [42] Superoxides fumC RFM443 Cell chip
EBHmp [42] Superoxides hmp RFM443 Cell chip
EBHJ [41] Superoxides sodA RFM443 0.015 mg/l paraquat Culture plate

All strains are E. coli with luxCDABE as the reporter