Primers and Probes for Real-Time qRT-PCR Analysis

Target Primers and probe Efficiency (%)
ADI1 For: 5′-GAGGGACAAGGAGGACCAGT-3′ 95
Rev: 5′-TGGCCTTCGTGTAGTTCTTCTC-3′
Probe: 5′-6FATCTTCATGGAGAAGGGAGACATGGTGACTAMRA-3′
CALR For: 5′-GGATCGAATCCAAACACAAGTC-3′ 98
Rev: 5′-TGGCTTGTCTGCAAACCTTTAT-3′
Probe: 5′-6FAM TGGCAAATTCGTTCTCAGTTCCGGCAA TAMRA-3′
EAF2/U19 For: 5′-CCAGGACTCCCAATCTTGTAAA-3′ 93
Rev: 5′-TAGCTTCTGCCTTCAGTTCTCTT-3′
Probe: 5′-6FAM CTCCATCTGAAGATAAGATGTCCCCAGCA TAMRA-3′
ELL2 For: 5′-TGACTGCATCCAGCAAACAT-3′ 98
Rev: 5′-TCGTTTGTTGCACACACTGTAA-3′
Probe: 5′-6FAM TCTCCAGCTCTGGAGCCTCCCA TAMRA-3′
GAPDH For: 5′-CATGTTCGTCATGGGTGTGA-3′ 95
Rev: 5′-GGTGCTAAGCAGTTGGTGGT-3′
Probe: 5′-6FAM ACAGCCTCAAGATCATCAGCAATGCCTC TAMRA-3′
PSA For: 5′-GTCCCGGTTGTCTTCCTCA-3′ 94
Rev: 5′-CACAATCCGAGACAGGATGAG-3′
Probe: 5′-6FAM TGTCCGTGACGTGGATTGGTGCTG TAMRA-3′