TABLE 1. Material constants b0, b1, b2, and b4 determined from vein inflation experiments22.

Fitting axial stress–strain data only Fitting axial and circumferential stress–strain data simultaneously


b0 b1 b2 b4 b0 b1 b2 b4
Vein 1 74.83 0.001 1.039 0.001 54.871 0.001 0.795 6.382
Vein 2 33.430 13.930 1.730 0.002 27.700 0.001 1.586 10.110
Vein 3 38.028 34.648 0.856 0.207 42.250 2.000 0.095 2.910
Vein 4 30.775 0.001 0.218 1.626 30.800 3.150 0.136 1.965
Vein 5 39.900 26.890 0.519 0.260 6.540 2.060 0.530 4.980
Vein 6 5.060 0.001 1.240 0.001 5.520 0.993 0.001 2.870
Vein 7 89.070 0.001 1.384 0.018 87.520 4.000 0.190 2.990
Vein 8 14.370 0.222 1.295 0.002 29.390 0.001 0.276 4.537

The material constants were determined by fitting Eq. (5) with the experimental data using Matlab.