TABLE 1. Material constants b0, b1, b2, and b4 determined from vein inflation experiments22.
Fitting axial stress–strain data only | Fitting axial and circumferential stress–strain data simultaneously | |||||||
---|---|---|---|---|---|---|---|---|
b0 | b1 | b2 | b4 | b0 | b1 | b2 | b4 | |
Vein 1 | 74.83 | 0.001 | 1.039 | 0.001 | 54.871 | 0.001 | 0.795 | 6.382 |
Vein 2 | 33.430 | 13.930 | 1.730 | 0.002 | 27.700 | 0.001 | 1.586 | 10.110 |
Vein 3 | 38.028 | 34.648 | 0.856 | 0.207 | 42.250 | 2.000 | 0.095 | 2.910 |
Vein 4 | 30.775 | 0.001 | 0.218 | 1.626 | 30.800 | 3.150 | 0.136 | 1.965 |
Vein 5 | 39.900 | 26.890 | 0.519 | 0.260 | 6.540 | 2.060 | 0.530 | 4.980 |
Vein 6 | 5.060 | 0.001 | 1.240 | 0.001 | 5.520 | 0.993 | 0.001 | 2.870 |
Vein 7 | 89.070 | 0.001 | 1.384 | 0.018 | 87.520 | 4.000 | 0.190 | 2.990 |
Vein 8 | 14.370 | 0.222 | 1.295 | 0.002 | 29.390 | 0.001 | 0.276 | 4.537 |
The material constants were determined by fitting Eq. (5) with the experimental data using Matlab.