Table 2.

Intra- and inter-observer variability for time-averaged, peak systolic and diastolic baseline WSS measurements. Values reported are mean ± standard deviation percent differences in WSS values over the entire ascending aorta.The intra- and inter-observer variability are less than the differences in mean values for WSS values between patients with AscAD and controls.

Time averaged WSS Peak Systolic WSS Diastolic Baseline WSS
AscAD Controls AscAD Controls AscAD Controls

Intra-observer Variability 1.16 ± 0.15 % 1.58 ± 2.01 % 5.29 ± 2.02 % 6.40 ± 7.94 % 1.50 ± 0.36 % 0.74 ± 0.88 %

Inter-observer Variability 3.69 ± 4.65 % 7.48 ± 6.47 % 13.26 ± 12.43 % 14.71 ± 12.57 % 8.66 ± 4.74 % 2.84 ± 1.60 %

% Difference of means 19.35% 18.18% 66.67 %