Fig 2.

Fig 2

Fig 2

Inhibitory effect of tetra-n-octylammonium bromide on hERG tail current measured in an automated whole cell patch clamp experiment. A. Representative electrophysiology recording from one automated patch clamp experiment. The voltage protocol used to induce the hERG current is shown at the bottom. B. The current vs. time plot (I–T plot) of the experiment from A.