Skip to main content
. 2010 Jul 13;35(5):705–711. doi: 10.1007/s00264-010-1084-7

Table 2.

Radiological parameters for specification of the centring of humeral head

Parameters Preoperative, mean ± SD (mm) Postoperative, mean ± SD (mm) Opposite side, mean ± SD (mm) P value, pre-/postoperative P value, postoperative/ opposite side
Modern adjustable prosthesis / Affinis; n = 106
AHD 10.08 ± 4.37 11.46 ± 4.85 10.14 ± 2.85 0.0010 0.4810
DTA 9.07 ± 8.31 13.44 ± 7.70 14.57 ± 5.03 0.0001 0.9650
DTC 56.81 ± 9.23 60.01 ± 7.28 61.76 ± 8.89 0.0001 0.1680
DCR 37.45 ± 7.08 36.01 ± 5.93 36.22 ± 5.65 0.0100 0.0940
DGR 25.49 ± 5.33 24.44 ± 3.47 23.66 ± 5.33 0.0120 0.4850
Second generation prostheses; n = 47
AHD 10.20 ± 5.36 8.49 ± 5.58 9.18 ± 2.76 0.013 0.956
DTA 9.07 ± 10.60 11.46 ± 10.74 9.71 ± 6.36 0.037 0.316
DTC 59.00 ± 11.91 59.00 ± 11.55 62.93 ± 8.80 0.467 0.064
DCR 35.17 ± 9.49 33.91 ± 8.93 35.50 ± 5.24 0.289 0.314
DGR 21.53 ± 6.36 21.57 ± 5.52 20.64 ± 4.75 0.978 0.422

AHD acriomio-humeral distance, DTA distance greater tuberosity/acromion, DTC distance greater tuberosity/coracoid, DCR distance coracoid/rotational centre, DGR distance glenoid/rotational centre