Skip to main content
. 2010 Nov 23;12(3):281–299. doi: 10.1007/s10162-010-0252-1

TABLE 2.

Model parameters derived from the mean NN functions (Fig. 6) assuming symmetrical roex(p,w,t) filters

Gap (ms) p t w k (dB) RMS (dB) BW3dB (Hz)
500 Hz
2 24.52 n/a 0.000 8.84 1.55 69
10 26.58 1.58 0.030 6.76 0.56 64
30 26.83 3.74 0.001 −3.98 1.33 63
50 27.67 n/a 0.000 −13.15 3.37 61
70 14.42 0.31 0.948 −24.51 0.00 38
4,000 Hz
2 49.29 1.96 0.009 4.18 0.58 280
10 48.48 2.27 0.002 1.45 1.01 280
30 51.12 2.20 0.005 −4.28 0.61 264
50 69.37 2.43 0.057 −10.86 0.08 208
70 478.22 17.13 0.044 −17.57 1.78 32

t is not applicable (n/a) when w = 0 (Eq. 1)