Skip to main content
. 2011 Feb 22;32(9):1114–1120. doi: 10.1093/eurheartj/ehr021

Table 2.

Follow-up data for the 90 patients in the cohort who underwent implantable cardioverter defibrillator placement

Total QTc ≤ 480 ms QTc > 480 ms
n 90 72 18
Male/female 53/37 41/31 12/6
Follow-up (years) 4.9 ± 3.3 5.0 ± 3.4 4.4 ± 3.0
Secondary prevention, n (%) 15 (17) 12 (17) 3 (17)
Mean no. of risk factors 1.8 ± 1.0 1.8 ± 0.9 1.9 ± 1.1
Presence of RF, n (%)
 NSVT on Holter 34 (38) 29 (40) 5 (28)
 LVWT >30 mm 24 (27) 17 (24) 7 (39)
 ABPR on exercise 21 (23) 15 (21) 6 (33)
 (Near)syncope 40 (44) 30 (42) 10 (56)
 Family Hx of sudden death 43 (48) 36 (50) 7 (39)
Appropriate discharges, n (%) 11 (12) 11 (15) 0 (0)

All values expressed as mean ± SD. It must be noted that as not always feasible in clinical practice, not all risk factors were routinely assessed for each patient with Holter monitor data least available for these patients. RF, risk factor; LVWT, left ventricular wall thickness; ABPR, abnormal blood pressure response.