Published in final edited form as: Mater Sci Eng C Mater Biol Appl. 2011 May 10;31(4):781–788. doi: 10.1016/j.msec.2010.11.029

Figure 4.

Figure 4

Fluid flow (KLM) model fits long-term cartilage stress-relaxation data. The KLM model can represent the majority of relaxation data (certainly all relaxation after about 100 seconds) but cannot accurately fit early relaxation. This observation is consistent with previous reports (e.g., [39]). Both the average error (A) and coefficient of determination (B) improve as the KLM model fit is started at later times. (C) The permeability converges on experimentally-measured values [7] as the model fit is started at later times. (D) Representative fit of the KLM model to cartilage stress-relaxation data.