Table 3.
Effect of Ser831 phosphomutations on recombinant homomeric GluA1 receptor coupling efficiency, ε
| γMEAN (pS) | ε | γMEAN (pS) | ε | Δε | N | |
|---|---|---|---|---|---|---|
| Control | CaMKII | |||||
| GluA1a | 12.0 ± 1.0 | 0.45 | 20.4 ± 2.9 | 0.84 | 0.39 | 9, 11 |
| GluA1-L497Yb | 12.4 ± 0.3 | 0.47 | 17.6 ± 0.4 | 0.71 | 0.24 | 19, 22 |
| S831A,S845A | S831E,S845A | |||||
| GluA1b,c | 8.3 ± 0.6 | 0.24 | 13.9 ± 0.9 | 0.54 | 0.30 | 23, 11 |
| GluA1- L497Yb | 9.4 ± 0.7 | 0.29 | 14.2 ± 0.6 | 0.54 | 0.25 | 18, 19 |
Homomeric GluA1 macroscopic current responses in outside-out patches from HEK cells were induced by 1 mM glutamate followed by a slow washout. Variance analysis of the response was used to estimate weighted mean conductance (γMEAN). Values are mean ± SEM.
Non-stationary variance analysis from Table 1
Stationary variance analysis
Currents recorded in the presence of 100 μM cyclothiazide