Skip to main content
. 2010 Mar 26;25(9):2039–2050. doi: 10.1002/jbmr.92

Table 4.

Correlation (Adjusted r 2) and Independent Predictors of Multilinear Regression for Prediction of the Gold Standard Mechanical Measurements by the Microstructural Measurements of µMRI and µCT

µCT‐based mechanical properties µMRI µCT
Independent predictors Constant Coefficient Adjusted r 2 Independent predictors Constant Coefficient Adjusted r 2
Whole‐bone stiffness BV/TV −626,731 2,774,470 0.60 BV/TV −1,501,086 6,615,513 0.76
Ct.Th 601,797
Ct.Th 616,230 Conn.D −87,140
BS/BV 55,260
Trabecular stiffness BV/TV −204,399 1,480,246 0.52 BV/TV −588,734 3,225,701 0.79
Conn.D −40,511
BS/BV 22,579
E 11 Conn.D −78 141 0.38 BV/TV −109 2,065 0.52
E 22 SMI 494 −207 0.55 BV/TV −96 3,085 0.68
Conn.D 118
E 33 Conn.D −2088 659 0.56 BV/TV −192 9,007 0.69
DA 1,136
G 23 Conn.D 297 82 0.53 BV/TV −56 1,981 0.65
SMI −125
G 31 Conn.D −51 99 0.38 BV/TV −73 1,444 0.52
G 12 Conn.D −26 62 0.45 BV/TV −39 904 0.60

Note: The order of predictors is the order in which predictors enter the stepwise regression model. All the predictions are statistically significant with p < .001.