Skip to main content
. 2011 Jun 24;342:d3621. doi: 10.1136/bmj.d3621

Table 6 .

Sensitivity and specificity for ambulatory monitoring compared with home monitoring of blood pressure

Study Diagnostic thresholds (mm Hg) Sensitivity % (95% CI) Specificity % (95% CI) Likelihood ratio (95% CI)
Ambulatory Home Positive Negative
Bayo 200634 135/85 135/85 76 (66 to 83) 50 (38 to 62) 1.51 (1.18 to 1.95) 0.49 (0.32 to 0.73)
Bayo 200634 135/85 130/80 88 (80 to 93) 34 (23 to 46) 1.33 (1.11 to 1.58) 0.36 (0.20 to 0.66)
Den Hond 200336 135/85 135/85 89 (84 to 92) 68 (43 to 87) 2.81 (1.45 to 5.45) 0.17 (0.10 to 0.27)
Denolle 199537 139/87 127/83 91 (59 to 100) 40 (5 to 85) 1.52 (0.72 to 3.18) 0.23 (0.03 to 1.96)
Larkin 199843 140/90 140/90 60 (39 to 79) 92 (79 to 98) 7.60 (2.45 to 23.58) 0.43 (0.27 to 0.71)
Llibre 200644 135/85 140/90 48 (35 to 61) 77 (68 to 85) 2.11 (1.34 to 3.33) 0.68 (0.52 to 0.88)
Stergiou 200049 140/90 140/90 75 (64 to 84) 76 (62 to 87) 3.11 (1.87 to 5.18) 0.33 (0.22 to 0.50)
Stergiou 200049 135/85 135/85 90 (83 to 95) 69 (50 to 84) 2.88 (1.72 to 4.84) 0.14 (0.08 to 0.27)