Skip to main content
. Author manuscript; available in PMC: 2011 Jun 24.
Published in final edited form as: J Biomed Mater Res A. 2009 Jun;89(3):632–641. doi: 10.1002/jbm.a.32015

Figure 4.

Figure 4

Scaffolds fabricated using the various spheres types were sintered with a 2:1 aspect ratio and tested using an Instron 4511 machine. A: Max load. B: Compressive Strength. C: Modulus. For each scaffold type (solid 100 μm, solid 500 μm, hollow core 500 μm) an n = 6 was measured. *Significant from solid 500 μm. The horizontal line in (C) represents the in vivo measured value of rat braincase. Here, p < 0.05.