Table 1B.
Average control Po, To and Tc before adding peptide, included to indicate baseline values for each parameter and the variability of control channel gating which necessitates normalization of test parameters
| (B). Control parameters for the following experiments | Po | To (ms) | Tc (ms) | |
| F loop peptide: 0.5 µM | Mean ± sem (14) | 0.013 ± 0.003 | 1.54 ± 0.95 | 195 ± 31 |
| range | 0.002–0.037 | 1.08–2.26 | 57–588 | |
| 1.0 µM | Mean ± sem (10) | 0.035 ± 0.014 | 1.47 ± 0.14 | 762 ± 370 |
| range | 0.0003–0.13 | 0.95–2.14 | 14–3472 | |
| 10 µM | Mean ± sem (10) | 0.050 ± 0.020 | 1.78 ± 0.29 | 167 ± 68 |
| range | 0.003–0.11 | 1.0–3.6 | 12–631 | |
| 50 µM | Mean ± sem (10) | 0.032 ± 0.015 | 1.96 ± 0.26 | 189 ± 51 |
| range | 0.005–0.12 | 1.4–3.6 | 16–430 | |
| 100 µM | Mean ± sem (5) | 0.108 ± 0.044 | 3.16 ± 0.60 | 86 ± 50 |
| range | 0.005–0.27 | 1.83–4.26 | 8–224 |