Table IV.

Minimum dose delivered to the prostate as a percentage of planned minimum dose for 0, 3, and 5 mm PTV margins, based on the first 10 fractions and the entire treatment course of each patient.

Minimum Dose Delivered to Prostate as a percentage of planned minimum dose (Goal >98%)
0 mm PTV 3 mm PTV 5 mm PTV
Patient Number 10 fx All 10 fx All 10 fx All
1 99 99 100 100 100 100
2 94 93 99 99 100 100
3 89 89 96 96 99 99
4 89 89 96 96 100 99
5 92 97 99 100 99 100
6 86 78 100 99 100 100
7 96 97 100 100 100 100
8 90 88 99 100 101 101
9 94 97 100 100 101 100
10 95 93 101 101 100 100
11 92 96 98 99 101 101
12 92 92 100 100 100 100
13 98 99 100 100 100 100
14 88 87 97 97 100 100
15 98 99 100 100 100 100