Skip to main content
. 2011 Apr 9;18(Pt 3):318–328. doi: 10.1107/S090904951100968X

(a).

At a frame rate of 12.5 Hz.

Dataset T_12 Accumulated dose (MGy) Observed reflections Multiplicity I/σ(I)〉 Rmeas (%) Wilson B value (Å2) Imean Mosaicity (°) I/I0
1 0.075 125855 4.2 22.35 4.3 24.16 217.27 0.037 1.00
2 0.149 125103 4.3 20.45 4.9 25.86 241.71 0.041 1.11
3 0.223 115807 4.3 18.47 5.4 27.86 177.92 0.045 0.82
4 0.298 108840 4.4 18.28 5.6 29.45 139.41 0.062 0.64
5 0.372 100527 4.4 18.74 5.6 30.18 120.55 0.076 0.56
6 0.447 72258 4.3 18.49 6.4 32.99 75.07 0.109 0.35
7 0.521 69073 4.6 19.67 6.2 32.91 60.08 0.134 0.28
8 0.596 63866 4.4 16.72 7.4 33.14 59.34 0.145 0.27
9 0.670 35686 4.3 13.35 11.4 33.72 26.10 0.209 0.12
10 0.745 39141 4.7 14.59 10.7 33.07 21.88 0.199 0.10
11 0.821 43755 4.5 14.82 10 32.84 23.12 0.194 0.11
12 0.894 25791 3.7 9.47 16 32.19 10.33 0.183 0.05