TABLE 1.

Average and standard deviation of clinical measurements before and after vision therapy with the change in parameters

Variable Before vision
therapy
After vision
therapy
Absolute value of
change in
parameter
NPC (cm) 13.4 ± 5.6 8.l ± 2.3 5.3 ± 3.4
RPC (cm) 20.8 ± 6.5 11.4 ± 2.2 9.4 ± 5.3
PFV at near using a BO prism bar (break) (Δ) 14 ± 4.5 40 ± 4.1 26 ± 6.2
Negative fusional vergence at near using a BI prism
    bar (break) (Δ)
13.9 ± 1.7 12.0 ± 3.7 1.9 ± 2.6
Near dissociated phoria (all subjects are exophores) (Δ) 9.0 ± 1.4 3.3 ± 1.9 5.8 ± 2.1
CISS 26 ± 7 10 ± 5 16 ± 10