Published in final edited form as: Phys Med Biol. 2011 May 25;56(12):3669–3684. doi: 10.1088/0031-9155/56/12/014

Table 1.

Numerical results of the comparison in 5D for the head neck case I around the seven-beam solution in figure 11 with parameters C = 50 and M = 32. Each face of the grid simplex is affiliated with one criterion: the criterion improves with decreasing distance to the face (see figure 5 and explanation). The negative value for the objective function difference indicates that the chosen seven-beam configuration stays superior if the spinal cord objective is further improved. If target coverage should be significantly improved however, a switch to the nine-beam configuration is indicated.

Center of faces
Grid center Target Mandible Left parotid Right parotid Spinal cord
Δ objective −7.9 10.0 0.03 3.5 −1.7 −13.2
Dominates? + 0 + +