Skip to main content
. 2011 Jun 25;4:215. doi: 10.1186/1756-0500-4-215

Table 2.

Primer probe sets.

Target Accession No. Sequence Melting TM efficiency
GAPDH NM_001002 F GAAGGTGAAGGTCGGAGTC 61.3 94
R GGGTGGAATCATATTGGAACA 63.2
P ATTTGGTCGTATTGGGCGCCTGGT 74.9
TFRC NM_003234 F ACCGGCACCATCAAGCT 64.5 94
R TGATCACGCCAGACTTTGC 65.2
P TGAAAATTCATATGTCCCTCGTGAGGCT 72.1
RPLP0 NM_001002 F CGGACGAGGATATGGGATTTG 67.2 89
R AGAAGTAAGCCTTTATTTCCTTGTTT 64.7
P TCACCAAAAAGCAACCAACTTAGCCAGT 72
GUSB NM_000181 F GCGTTCCTTTTGCGAGGAGA 68.6 74
R GGTGGTATCAGTCTTGCTCAA 64.7
P ACCAGGTATCCCCACTCAGTAGCCAAG 72
HPRT1 NM_000194 F TGGACTAATTATGGACAGGACTGAA 64.4 103
R GTAATCCAGCAGGTCAGCAA 62.8
P CTTGCTCGAGATGTGATGAAGGAGATGG 73.7
UPA NM_002658 F AGGGCAGCACTGTGAAATAGATAAGT 65.7 97
R CATGGTACGTTTGCTGAAGGA 64.8
P TTACCGAGGAAAGGCCAGCACTGACA 75.3
ACTB NM_001101 F CAGCAGATGTGGATCAGCAAG 65.9 95
R GCATTTGCGGTGGACGAT 67.1
P AGGAGTATGACGAGTCCGGCCCC 73.8

Probes were labeled with 5' FAM and 3' TAMRA.