Table 3. Data-collection and processing statistics (trigonal crystal form).

Values in parentheses are for the highest resolution shell.

Compound Apo Vanadate S1 2 4 5 7 10
Source
Wavelength 1.54178 1.0 1.54178 1.54178 1.54178 1.54178 1.54178 1.54178
Detector Rigaku R-AXIS IV++ ADSC Q210 Rigaku R-AXIS IV++ Rigaku R-AXIS IV++ Rigaku R-AXIS IV++ Rigaku R-AXIS IV++ Rigaku R-AXIS IV++ Rigaku R-AXIS IV++
Crystal-to-detector distance (mm) 180 170 150 175 175 175 120 180
Rotation range/image (°) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Total rotation range (°) 180 180 120 180 180 180 120 180
Exposure time per image (min) 4 5 s 3 3 3 8 4 4
Space group P3221 P3221 P3221 P3221 P3221 P3221 P3221 P3221
Unit-cell parameters (Å, °) a = b = 75.2, c = 152.3 a = b = 75.4, c = 151.0 a = b = 75.5, c = 152.1 a = b = 75.5, c = 152.9 a = b = 75.4, c = 153.8 a = b = 75.7, c = 152.2 a = b = 75.5, c = 152.6 a = b = 75.5, c = 151.8
Mosaicity range (°) 1.3–2.0 0.5–0.6 0.4 0.8–1.4 0.7–1.1 0.7–0.9 1.0–1.1 0.4–0.9
Resolution range (Å) 50–2.41 (2.5–2.41) 50–1.8 (1.86–1.80) 50–2.05 (2.12–2.05) 50–2.40 (2.49–2.4) 50–2.26 (2.34–2.26) 50–2.26 (2.34–2.26) 50–2.05 (2.12–2.05) 50–2.40 (2.49–2.4)
Total No. of measured reflections§ 169546 (≥13336) 494573 (≥35913) 215486 (≥1681) 163183 (≥14661) 227584 (≥18692) 213656 (≥18020) 217352 (≥19837) 164368 (≥15531)
Unique reflections 19097 (1795) 45117 (4250) 30938 (2844) 20534 (2008) 24039 (2373) 23970 (2282) 32729 (3202) 20275 (1989)
Multiplicity 8.9 (8.6) 11.0 (10.5) 7.0 (7.2) 7.9 (7.9) 9.5 (9.0) 8.9 (8.7) 6.6 (6.7) 8.1 (8.6)
Completeness (%) 96.0 (92.0) 96.6 (92.1) 95.6 (89.9) 99.8 (100) 99.7 (99.7) 98.2 (96.2) 99.7 (99.7) 99.5 (99.4)
Rmerge (%) 18.6 (53.7) 7.3 (61.4) 4.0 (13.9) 18.6 (65.1) 9.8 (52.1) 10.9 (41.6) 7.3 (67.8) 20.7 (78.1)
Mean I/σ(I) 8.0 (4.3) 24.1 (4.1) 37.6 (14.4) 9.0 (3.5) 16.4 (4.7) 14.5 (5.4) 18.0 (3.2) 9.2 (4.6)
Overall B from Wilson plot (Å2) 58 32 31 58 50 49 42 54

Rigaku FR-E running at 45 kV and 45 mA and equipped with Rigaku VariMaxHR confocal optics.

Beamline 17-ID (IMCA-CAT) at the Advanced Photon Source at Argonne National Laboratory, Argonne, Illinois, USA as configured in 2005–2006.

§

If any reflections are measured more than four times then one cannot extract from HKL-2000 output the total number of measured reflections in a shell but merely a lower limit, hence the use of the ≥ sign.

R merge = Inline graphic Inline graphic, where I i(hkl) is the ith observation of reflection hkl and 〈I(hkl)〉 is the weighted average intensity for all observations i of reflection hkl.