Table 2.

Model-based estimated difference between shear stiffness (μ) as calculated using local frequency estimation (LFE) and principal frequency analysis (PF) methods. At a pressure of 6 cm H20 and above, the difference becomes statistically significantly different.

Ptp (cm H2O) Est. diff. in μ [LFE-PF) (kPa) Standard Error (kPa) Degrees of Freedom t-statistic p
3 -0.65 0.33 18 -1.99 0.0615
6 -0.84 0.33 18 -2.57 0.0194
9 -1.49 0.32 18 -4.67 0.0002
10 -1.56 0.32 18 -4.89 0.0001
12 -1.95 0.32 18 -6.11 <.0001
15 -2.11 0.32 18 -6.60 <.0001