Skip to main content
. 2011 Aug 15;53(4):334–340. doi: 10.1093/cid/cir402

Table 3.

Characteristics of Treatment and Outcome of 98 Patients With Total Hip or Knee Prosthesis Infection Due to Staphylococcus aureus

Variable Rifampin treatment (n = 68)
No Rifampin treatment (n = 30)
P
Fluoroquinolone combinations (n = 39) Other rifampin combinations (n = 29) Linezolid monotherapy (n = 11) Other treatment (n = 19)
Debridement-retention (n = 41) 15/16 (93.8) 10/15 (66.7) 3/3 (100) 4/7 (57.1) .11
One-stage replacement (n = 14) 6/6 (100) 5/5 (100) 1/1 (100) 2/2 (100)
Two-stage replacement (n = 26) 12/12 (100) 6/9 (66.7) 4/4 (100) 0/1 (0) .01
Arthroplastic resection (n = 9) 1/1 (100) 0 1/3 (33.3) 2/5 (40)
Arthrodesis (n = 8) 3/4 (75) 0 0 2/4 (50)
     Total 37/39 (94.8) 21/29 (72.4) 9/11 (81.8) 10/19 (52.6) .002

NOTE.  Data are proportion (%) of patients with remission.