Table 1.
Mechanical and geometry results of aortas from apoE−/− and apoE−/−xTgSMC-Cat mice with and without ANG II treatment
ANG II | λz | d, mm | B, mm | H, μm | O.A., ° | |
---|---|---|---|---|---|---|
apoE−/− | − | 1.48 ± 0.005 | 1.37 ± 0.03 | 0.343 ± 0.02 | 89 ± 2.1 | 130 ± 1 |
+ | 1.38 ± 0.04* | 1.39 ± 0.08 | 0.342 ± 0.06 | 89 ± 1.9 | 198 ± 8* | |
apoE−/−xTgSMC-Cat | − | 1.26 ± 0.008* | 1.16 ± 0.01*† | 0.347 ± 0.005 | 98 ± 2.1*† | 130 ± 8† |
+ | 1.23 ± 0.05* | – | – | 88 ± 1.6‡ | 130 ± 5† |
Values are means ± SE. Stretch ratio and loaded diameter data were acquired during isolated aortic inflation. Unloaded morphology was acquired from histological analysis of bisected aortic rings used in opening angle (O.A.) measurement. apoE−/−, apolipoprotein E-deficient mice; apoE−/−xTgSMC-Cat, apoE−/− mice that overexpress catalase in vascular smooth muscle cells; λz, axial stretch ratio (l/L), where l is loaded length and L is unloaded length; d, ex vivo loaded diameter; B, unloaded outer radius; H, unloaded thickness.
P < 0.05 vs. apoE−/−.
P < 0.05 vs. apoE−/− + ANG II.
P < 0.05 vs. apoE−/−xTgSMC-Cat.