Skip to main content
. 2011 May 6;301(2):H355–H362. doi: 10.1152/ajpheart.00040.2011

Table 1.

Mechanical and geometry results of aortas from apoE−/− and apoE−/−xTgSMC-Cat mice with and without ANG II treatment

ANG II λz d, mm B, mm H, μm O.A., °
apoE−/− 1.48 ± 0.005 1.37 ± 0.03 0.343 ± 0.02 89 ± 2.1 130 ± 1
+ 1.38 ± 0.04* 1.39 ± 0.08 0.342 ± 0.06 89 ± 1.9 198 ± 8*
apoE−/−xTgSMC-Cat 1.26 ± 0.008* 1.16 ± 0.01* 0.347 ± 0.005 98 ± 2.1* 130 ± 8
+ 1.23 ± 0.05* 88 ± 1.6 130 ± 5

Values are means ± SE. Stretch ratio and loaded diameter data were acquired during isolated aortic inflation. Unloaded morphology was acquired from histological analysis of bisected aortic rings used in opening angle (O.A.) measurement. apoE−/−, apolipoprotein E-deficient mice; apoE−/−xTgSMC-Cat, apoE−/− mice that overexpress catalase in vascular smooth muscle cells; λz, axial stretch ratio (l/L), where l is loaded length and L is unloaded length; d, ex vivo loaded diameter; B, unloaded outer radius; H, unloaded thickness.

*

P < 0.05 vs. apoE−/−.

P < 0.05 vs. apoE−/− + ANG II.

P < 0.05 vs. apoE−/−xTgSMC-Cat.