Skip to main content
. 2011 Jul;130(1):376–388. doi: 10.1121/1.3592521

Table 4.

Lower and upper cutoff frequencies (Hz) for each channel condition are shown. The active electrode used for each channel is shown in parentheses.

  Frequency allocation for each channel condition  
Number of channels 1 2 4 8 12 16
1 250–8700 (2) 250–1387 (2) 250–698 (4) 250–494 (2) 250–440 (1) 250–416 (1)
2   1389–8700 (8) 698–1386 (8) 494–698 (4) 440–554 (2) 416–494 (2)
3     1386–2762 (12) 698–982 (6) 554–698 (3) 494–587 (3)
4     2762–8700 (16) 982–1388 (8) 698–876 (5) 587–697 (4)
5       1388–1956 (10) 876–1104 (6) 697–828 (5)
6       1956–2764 (12) 1104–1386 (7) 828–983 (6)
7       2764–3896 (14) 1386–1746 (9) 983–1168 (7)
8       3896–8700 (16) 1746–2194 (10) 1168–1387 (8)
9         2194–2746 (11) 1387–1648 (9)
10         2746–3472 (13) 1648–1958 (10)
11         3472–4376 (14) 1958–2326 (11)
12         4376–8700 (15) 2326–2762 (12)
13           2762–3281 (13)
14           3281–3898 (14)
15           3898–4630 (15)
16           4630–8700 (16)