Skip to main content
. Author manuscript; available in PMC: 2011 Aug 15.
Published in final edited form as: J Magn Reson Imaging. 2011 Apr;33(4):931–939. doi: 10.1002/jmri.22479

Table 2.

The arterial/venous (A/V) and blood/muscle (B/M) contrast, and the arterial blood SNR measurements on peripheral angiograms along with p values from Student’s t-tests.

Method PS-SSFP IDEAL P Value
A/V1 1.29±0.04 1.62±0.02 <0.10
A/V2 1.23±0.09 1.51±0.17 <0.10
B/M1 3.65±0.40 2.75±0.31 <0.10
B/M2 2.66±0.09 2.15±0.30 >0.10
SNR1 16.76±2.43 19.77±1.76 <0.10
SNR2 13.76±2.57 19.51±1.71 <0.10

The superscripts denote the first and second sets of measurements performed on the anterior tibial and dorsalis pedis arteries respectively.