Skip to main content
. 2011 Aug 19;6(8):e23470. doi: 10.1371/journal.pone.0023470

Table 3. Effect of filter pore sizes on aflatoxin inhibition.

Treatment Pore Size Membrane Material Mean Amount of B1 (ppb)
Check (53/0.01% TX) 0.4 µm Hydrophilic PTFE 605.93±45.78 a *
0.4 µm Polycarbonate 425.22±82.60 bc
200 µm Polyester Mesh 528.02±80.38 ab
Separated (53/51) 0.4 µm Hydrophilic PTFE 507.54±87.49 ab
0.4 µm Polycarbonate 586.10±44.52 ab
3 µm Polycarbonate 511.34±115.68 ab
12 µm Polycarbonate 317.59±102.09 c
74 µm Polyester Mesh 1.82±1.65 d
200 µm Polyester Mesh 0.02±0.02 d
Together (53+51/53+51) 0.4 µm Hydrophilic PTFE 10.65±2.18 d
0.4 µm Polycarbonate 0.21±0.14 d
200 µm Polyester Mesh 0.01±0.01 d

Aflatoxin B1 production by toxigenic isolate 53 in the filter insert-plate well system when grown together or separated from the atoxigenic isolate 51 by a range of filter insert membrane pore sizes.

*Means followed by the same letter are not significantly different at the α = 0.05 level.