Table 3.

Sensitivity, Specificity, Accuracy of Epoch-by-Epoch Comparison Polysomnography and Actigraphy

JIA Asthma Controls
n = 34 n = 19 n = 18
Sensitivity
Low Thresholda .98 ± .01 .97 ± .02 .98 ± .01
Medium Threshold b .96 ± .02 .94 ± .03 .95 ± .02
High Threshold c .93 ± .03 .88 ± .04 .90 ± .04
Specificity
Low Threshold d .38 ± .20 .60 ± .16 .55 ± .15
Medium Threshold e .51 ± .21 .73 ± .13 .69 ± .15
High Threshold f .62 ± .18 .80 ± .11 .77 ± .15
Accuracy
Low Threshold .88 ± .07 .90 ± .04 .90 ± .04
Medium Threshold .89 ± .06 .89 ± .04 .90 ± .03
High Threshold .88 ± .05 .87 ± .04 .87 ± .02

Data are mean ± SD. All p = Pair wise comparison, Tukey HSD