Groups # (n) Scan rate Overlap Fluence Water Etch Mean (MPa) Statistical groupsa
Dentin set              
D1 (10) 25-mm/s 1/3 18 H2O etch 29.9 (6.4) 3
D2 (10) 25-mm/s 1/3 18 H2O   14.1 (7.2) 8,3-6
D3 (10) 50-mm/s 1/3 18 H2O etch 21.3 (5.5) 1,2,4,5
D4 (10) 50-mm/s 1/3 18 H2O   17.3 (3) 2,3,5,6
D5 (10) 50-mm/s 1/3 18   etch 14.1 (5.3) 8,2-4,6
D6 (10) 50-mm/s 1/3 18     11.3 (5.8) 8,2,4,5
D7 (10) positive control       etch 39.0 (5.4)  
D8 (10) negative control         5.1 (8) 2,5,6
Enamel set 1              
AE1 (10) 50-mm/s 1/3 20 H2O etch 31.2(2.5)  
AE2 (10) 50-mm/s 1/3 20 H2O   5.2(2.4)  
AE3 (10) positive control       etch 37 (3.6)  
Enamel set 2              
BE1 (10) 30-mm/s 2/9 13 H2O etch 34.1(4.6) 2,3,6
BE2 (12) 60-mm/s 4/9 13 H2O etch 34.9(5.1) 1,3,6
BE3 (12) 135-mm/s 1 13 H2O etch 33.4(5.5) 1,2,6
BE4 (10) 30-mm/s H-250 13 & 42 H2O   15.3(3.9)  
BE5 (10) 30-mm/s H-500 13 & 42 H2O   5.8(3.1)  
BE6 (10) positive control       etch 36.6(4.9) 1-3
a

Groups with similar numbers are statistically similar (p>0.05) in each set, D, AE, and BE.