Published in final edited form as: Build Environ. 2011 Oct;46(11):2303–2313. doi: 10.1016/j.buildenv.2011.05.012

Table 5.

PM, PNC and CO2 concentrations in bedrooms with and without ETS. "None" is based on household survey; "Yes-Tracer" indicates ETS tracer was detected; "Yes-Survey" indicates indoor smoking may have occurred based on caregiver survey.

ETS Present N Ave SD Med 90th p-valuea
PM (µg/m3) None 93 25.3 19.8 18.8 53.6
Yes - Tracer 22 40.3 30.8 30.6 86.0 0.005
Yes - Survey 34 34.2 22.9 32.4 58.1 0.068
0.3–1.0 µm PNC (#/liter) None 91 55,006 42,234 40,384 115,354
Yes - Tracer 22 136,009 81,200 117,121 239,492 <0.001
Yes - Survey 31 111,563 80,016 84,612 197,548 <0.001
1–5 µm PNC (#/liter) None 91 1,317 1,315 907 2,549
Yes - Tracer 22 2,109 1,518 1,693 3,960 0.010
Yes - Survey 31 1,710 1,274 1,357 3,660 0.241
CO2 (ppm) None 100 1,126 458 995 1,789
Yes - Tracer 23 1,237 500 1,180 1,874 0.305
Yes - Survey 34 1,160 453 1,099 1,822 0.844
a

p-value from independent-samples t-test.