Skip to main content
. 2011 Jul 25;2011:341546. doi: 10.5402/2011/341546

Table 1.

Discrepancies (Mean ± SD, in μm) of stone dies obtained from the different impression materials and techniques. Homogeneous grouping determined by Tukey multiple comparison test (α = 0.05). Positive discrepancies indicate that the dies were larger, while negative discrepancies indicate that the dies were smaller, when compared to the original stainless steel die.

Group (n = 10) Mean (μm) ± SD Homogeneous grouping*
Perfectim single-step 79.40 ± 14.11 a
Impregum single-step 63.52 ± 16.60 a
Perfectim 2-step −201.86 ± 28.58 b
Impregum 2-step −290.94 ± 71.64 c

*Mean values followed by different letters correspond to significant differences.