Skip to main content
. Author manuscript; available in PMC: 2011 Sep 22.
Published in final edited form as: Open Pacing Electrophysiol Ther J. 2010;3:45–54.

Table 1.

Comparison of CVSim Versions Available from PhysioNet

XCVSim RCVSim CVSim-6 CVSim-21
Circulation model Linear lumped-parameter Nonlinear lumped-parameter Linear lumped-parameter Nonlinear venous pressure-volume relationships
Compartments 6 6 6 17 vascular compartments, 4 cardiac compartments, 1 interstitial compartment
Control model Arterial baroreflex Short-term regulation Arterial baroreflex Short-term regulation
Other model features Realistic parameters Resting perturbations Realistic parameters Orthostatic stress test simulations
Progammable parameter changes No Yes No No
Library of simulated “patients” Yes No Yes No
User interface X11 GUI Command-line (text) interface; scripting Java GUI Java GUI
Plotting and printing Integrated External, via WAVE and gnuplot Integrated Integrated
Output can be stored No Yes No No
Software sources C MATLAB Model in C GUI in Java Model in C GUI in Java
Needed to create executables ANSI/ISO C compiler, Xt library MATLAB ANSI/ISO C compiler, Sun Java SDK ANSI/ISO C compiler, Sun Java SDK
Precompiled executables on PhysioNet GNU/Linux GNU/Linux GNU/Linux, Mac OS X, Windows None
URL http://physionet.org/physiotools/cvsim