Circulation model |
Linear lumped-parameter |
Nonlinear lumped-parameter |
Linear lumped-parameter |
Nonlinear venous pressure-volume relationships |
Compartments |
6 |
6 |
6 |
17 vascular compartments, 4 cardiac compartments, 1 interstitial compartment |
Control model |
Arterial baroreflex |
Short-term regulation |
Arterial baroreflex |
Short-term regulation |
Other model features |
Realistic parameters |
Resting perturbations |
Realistic parameters |
Orthostatic stress test simulations |
Progammable parameter changes |
No |
Yes |
No |
No |
Library of simulated “patients” |
Yes |
No |
Yes |
No |
User interface |
X11 GUI |
Command-line (text) interface; scripting |
Java GUI |
Java GUI |
Plotting and printing |
Integrated |
External, via WAVE and gnuplot |
Integrated |
Integrated |
Output can be stored |
No |
Yes |
No |
No |
Software sources |
C |
MATLAB |
Model in C GUI in Java |
Model in C GUI in Java |
Needed to create executables |
ANSI/ISO C compiler, Xt library |
MATLAB |
ANSI/ISO C compiler, Sun Java SDK |
ANSI/ISO C compiler, Sun Java SDK |
Precompiled executables on PhysioNet |
GNU/Linux |
GNU/Linux |
GNU/Linux, Mac OS X, Windows |
None |
URL |
http://physionet.org/physiotools/cvsim |