Skip to main content
. 2011 Aug 17;12:346. doi: 10.1186/1471-2105-12-346

Table 3.

Comparison of probTag and PepNovoTag (version 3

Tag Identification Performance

Tag Length Methods + - Accuracya
3 PepNovoTag 790 210 79.00%
probTag 876 106 89.21%
4 PepNovoTag 709 291 70.90%
probTag 760 164 82.25%
5 PepNovoTag 610 390 61.00%
probTag 616 209 74.67%

a Tag identification was "correct" if the tag was contained in the real peptide. Accuracy denotes the ratio of "correct" tag identification.