. 2011 Sep 29;52(10):7792–7798. doi: 10.1167/iovs.11-8023

Table 2.

Summary of Correlation Analysis

Measurement Parameters CSA Group
LA Group*
CME SRF PED CME SRF PED
Correlation of simplified measurements (R2) (n = 26) (n = 26) (n = 26) (n = 19) (n = 19) (n = 19)
    B-scan count 0.80 0.88 0.70 0.97 0.97 0.39
    A-scan count 0.77 0.88 0.70 0.95 0.88 0.07
    Maximum height 0.96 0.87 0.32 0.98 0.89 0.43
    B-scan count × maximum height 0.95 0.95 0.67 0.99 0.97 0.53
    A-scan count × maximum height 0.96 0.96 0.70 0.99 0.98 0.49
    Estimated area × maximum height 0.93 0.96 0.81 0.98 0.99 0.52
Correlation of automated measurements (R2)
    Cirrus HD-OCT (n = 6) (n = 6) (n = 6) (n = 0) (n = 4) (n = 4)
        FCS 0.47 0.01 0.10 0.72 0.42
        Macular volume 0.08 0.38 0.08 0.63 0.34
    3D-OCT-1000 (n = 20) (n = 20) (n = 20) (n = 15) (n = 15) (n = 15)
        FCS 0.19 0.24 0.17 0.33 0.81 0.26
        Macular volume 0.60 0.62 0.16 0.27 0.70 0.72

The coefficient of determination (R2) for each parameter is shown for the CSA group and the LA group separately. The simplified measurements are listed in the upper half, whereas the automated measurements collected from the OCT devices are shown in the lower half.

*

For the longitudinal group measurements are given as change from the previous visit.