Skip to main content
. 2011 Oct 1;2011:640535. doi: 10.1155/2011/640535

Table 1.

Comparison between DMC and controls for VEP latencies.

Age VEP components DMC Controls P*
Latency (ms) Latency (ms)
Mean ± SD Confidence interval Mean ± SD Confidence interval
−99% +99% −99% +99%
2 months Right (O2)
III 136.2 ± 29.9 114.2 158.2 109.0 ± 31.1 89.8 129.3 <0.01
IV 190.9 ± 33.4 166.3 215.5 156.6 ± 30.8 137.4 175.7 <0.01
V 275.8 ± 50.1 238.9 312.8 223.6 ± 47.1 194.4 252.9 <0.01
Left (O1)
III 132.3 ± 29.6 110.5 154.1 108.4 ± 31.6 88.7 128.0 <0.05
IV 187.8 ± 37.1 160.4 215.1 156.7 ± 31.7 137.0 176.4 <0.01
V 267.2 ± 47.3 232.3 302.1 220.1 ± 50.0 189.0 251.1 <0.01

3 years Right (O2)
III 71.53 ± 15.2 62.3 78.4 67.63 ± 9.0 61.5 74.0 NS
IV 105.53 ± 13.1 98.7 114.5 99.96 ± 8.8 93.8 106.1 <0.05
V 149.03 ± 36.2 133.2 174.2 149.05 ± 22.5 133.5 165.5 NS
Left (O1)
III 74.47 ± 13.4 65.8 81.3 68.02 ± 9.7 62.0 74.0 NS
IV 106.13 ± 14.0 98.4 116.0 98.69 ± 10.2 91.8 105.6 <0.05
V 151.12 ± 43.3 135.9 180.1 150.0 ± 22.4 132.8 167.3 NS

*ANOVA (post hoc comparison with correction for multiple comparisons—Bonferroni test).