Skip to main content
. 2011 Sep;130(3):1618–1627. doi: 10.1121/1.3613708

Table 2.

Contact pressure estimates.

Methods Flow rate Q (l∕min) Peak contact pressure Pc (kPa) Error (%)
Direct measurement 43.3 0.59 N∕A
45.2 0.63 N∕A  
Hertzian model 43.3 0.63 6.6
45.2 0.74 17.5  
FEM prediction 43.3 0.51 N∕A
45.2 0.99 N∕A