Table 2.
Category | Accuracy(%) | Standard Deviation(%) |
---|---|---|
Case 1 | 98.40% | 0.23% |
Case 2 | 92.06% | 0.98% |
Case 3 | 89.92% | 0.77% |
Accuracy of our method in 3 different categories. In Case 1 both the inserted sequence and the region in the reference is unique. In Case 2 the copied sequence is inserted in a unique region in the reference, while in Case 3 the copied insertion contains a unique insertion as well. For each case, 5 simulations were performed.