Skip to main content
. Author manuscript; available in PMC: 2011 Oct 17.
Published in final edited form as: Proc IEEE Int Symp Biomed Imaging. 2009:779–782. doi: 10.1109/ISBI.2009.5193165

Table 1. Absolute (mm) and normalized (%) distance between semi-automatic and manual segmentations (Alg-Clin) and between two manual segmentations by the same clinician (Clin-Clin).

Data Set dmax (mm) Distance (mm)
(mean ± std. dev.)
Distance (%)
(mean ± std. dev.)
Alg-Clin Clin-Clin Alg-Clin Clin-Clin
1 37.97 1.09±0.56 1.20±0.60 2.88±1.48 3.17±1.57
2 29.68 0.91±0.47 1.04±0.54 3.05±1.57 3.49±1.82
3 29.37 1.29±0.89 1.31±2.24 4.38±3.03 4.48±7.61
4 28.04 1.30±0.87 0.55±0.30 4.62±3.12 1.96±1.07
Mean 31.27 1.15±0.70 1.03±0.92 3.73±2.30 3.28±3.67