Table 1.

LOQ, mean slope (SD), mean intercept (SD), r2 range, and linear range (n = 10) for low and high calibration curves for THC, 11-OH-THC, and THCCOOH in whole blood by SPE and 2D electron impact GC-MS.

Compound LOQ, μg/L Curve Mean slope (SD) Mean intercept (SD) r2, range Linear range, μg/L
THC 0.25 Low 0.171 (0.013) 0.005 (0.004) 0.995–1.000 0.25–25
High 0.137 (0.014) 0.590 (0.558) 0.995–1.000 25–100
11-OH-THC 0.5 Low 0.183 (0.013) 0.009 (0.005) 0.994–0.999 0.5–25
High 0.121 (0.013) 1.271 (0.395) 0.991–1.000 10–75
THCCOOH 0.25 Low 0.191 (0.013) 0.004 (0.003) 0.996–1.000 0.25–25
High 0.149 (0.016) 0.814 (0.623) 0.992–1.000 25–100