Skip to main content
. Author manuscript; available in PMC: 2012 Sep 1.
Published in final edited form as: J Magn Reson Imaging. 2011 Jul 18;34(3):696–701. doi: 10.1002/jmri.22663

Table 1.

Lumen area, total vessel area, and vessel wall area measurements obtained with BB 3D SSFP in the popliteal artery (n = 11).

DIR SPSAT MSPREP T2IR
Lumen area (mm2)
 Proximal 29 ± 8* 27 ± 10* 33 ± 10 33 ± 10
 Middle 23 ± 7* 20 ± 7* 29 ± 8 29 ± 8
 Distal 16 ± 5* 17 ± 5* 24 ± 8 23 ± 6

Total vessel area (mm2)
 Proximal 52 ± 11* 51 ± 12* 55 ± 15 55 ± 14
 Middle 42 ± 11* 39 ± 10* 47 ± 11 48 ± 11
 Distal 31 ± 8* 32 ± 8 * 39 ± 10 39 ± 9

Vessel wall area (mm2)
 Proximal 23 ± 4 24 ± 6 22 ± 6 21 ± 5
 Middle 19 ± 5 20 ± 3 19 ± 3 19 ± 3
 Distal 15 ± 3 15 ± 3 15 ± 3 16 ± 3

indicates significance compared to T2IR (P < 0.05).

*

indicates significance compared to MSPREP (P < 0.05).