Fig. 1.
A series of CAP responses evoked by electrical and acoustic stimuli. Both of the ECAP and ACAP data are collected at 16 kHz and from the same guinea pig. As electrical or acoustic level was raised from low levels, N1 is the first to appear, followed by N2 at higher intensities. Except for the shorter latency, ECAP’s waveform is very similar to that of ACAP.