Table 2.
Single FIT | "one of two FITs+" | "two of two FITs+" | "mean of two FITs+" | |||||
---|---|---|---|---|---|---|---|---|
Cut-off value | Sens | Spec | Sens | Spec | Sens | Spec | Sens | Spec |
Cut-off 50 | 47, 6% | 88, 2% | 54, 0% | 83, 0% | 43, 5% | 93, 2% | 52, 4% | 88, 8% |
N | 59/124 | 844/957 | 67/124 | 794/957 | 54/124 | 892/957 | 65/124 | 850/957 |
(CI) | (39-57) | (86-90) | (45-63) | (80-85) | (35-53) | (91-95) | (43-61) | (87-91) |
Cut-off 75 | 46, 0% | 90, 5% | 52, 4% | 87, 4% | 41, 1% | 94, 4% | 46, 8% | 91, 3% |
N | 57/124 | 866/957 | 65/124 | 836/957 | 51/124 | 903/957 | 58/124 | 874/957 |
(CI) | (37-55) | (88-92) | (43-61) | (85-89) | (32-50) | (93-96) | (38-56) | (89-93) |
Cut-off 100 | 45, 2% | 92, 5% | 51, 6% | 89, 8% | 39, 5% | 95, 5% | 44, 4% | 92, 8% |
N | 56/124 | 885/957 | 64/124 | 859/957 | 49/124 | 914/957 | 55/124 | 888/957 |
(CI) | (36-54) | (91-94) | (42-61) | (88-92) | (31-49) | (94-9s7) | (35-54) | (91-94) |
Cut-off 150 | 42, 7% | 94, 6% | 47, 6% | 92, 2% | 35, 5% | 96, 8% | 38, 7% | 94, 1% |
N | 53/124 | 905/957 | 59/124 | 882/957 | 44/124 | 926/957 | 48/124 | 901/957 |
(CI) | (34-52) | (93-96) | (39-57) | (89-93) | (27-45) | (95-98) | (30-48) | (92-96) |
Cut-off 200 | 37, 9% | 95, 1% | 41, 9% | 93, 2% | 34, 7% | 97, 5% | 37, 1% | 96, 1% |
N | 47/124 | 910/957 | 52/124 | 892/957 | 43/124 | 933/957 | 46/124 | 920/957 |
(CI) | (29-47) | (94-96) | (39-57) | (91-95) | (26-44) | (96-98) | (29-46) | (95-97) |
Test characteristics at different cut-off values (ng/ml) of single and three strategies of double FIT sampling for detection of screen relevant neoplasia in 1081* individuals referred for colonoscopy (SRN in 124, no AA nor CRC in 957). *15 cases of late stage CRC were excluded since they were not considered screen relevant.
FIT = faecal immunochemical test, SRN = screen relevant neoplasia, AA = advanced adenoma, CRC = colorectal cancer, "one of two FITs+" = at least one of both FITs above the cut-off value, "two of two FITs+" = both FITs above the cut-off value, "mean of two FITs+" = geometric mean of both FITs above the cut-off value, CI = confidence interval, sens = sensitivity, spec = specificity