Skip to main content
. Author manuscript; available in PMC: 2012 Aug 17.
Published in final edited form as: Ind Eng Chem Res. 2011 Aug 17;50(16):9525–9531. doi: 10.1021/ie200669b

Table 2.

Measured and “fit” nickel corrosion rates (35°C, 10A).

pH Nickel corrosion rate without (w/o) nitrogen sparging (×106 mol L-1 min-1) Nickel corrosion rate with nitrogen sparging (×106 mol L-1 min-1)
(35°C, 10A) Measured “Fit” Measured “Fit”
3.5 57 38 22 21
4.0 12 29 2.6 10
4.5 4.1 17 1.6 3.4
5.0 2.8 10 1.2 0.9