Skip to main content
. Author manuscript; available in PMC: 2012 Nov 1.
Published in final edited form as: Optom Vis Sci. 2011 Nov;88(11):1288–1297. doi: 10.1097/OPX.0b013e31822b3746

Table 1.

Mean sensitivity comparison between sectors. The data are presented to show a retinal view (as for the MP-1) and MP-1 data are given in HFA equivalent dB units. Superior-inferior and nasal-temporal comparisons were calculated for sectors divided at the midline. The foveal and peripheral locations included the central 16 and peripheral 52 locations, respectively. Unpaired t tests were performed to compare sectors. Significance differences are indicated in bold.

Mean Mean difference p Mean Mean difference p Mean Mean difference p
HFA Superior 33.09 0.57 0.012 Nasal 32.86 0.10 0.677 Foveal 34.01 1.57 < 0.001
Inferior 32.52 Temporal 32.76 Peripheral 32.44

MP-1 Superior 32.10 1.47 < 0.001 Nasal 32.76 0.14 0.615 Foveal 33.54 0.93 0.004
Inferior 33.56 Temporal 32.90 Peripheral 32.61