Skip to main content
. Author manuscript; available in PMC: 2011 Nov 2.
Published in final edited form as: J Neurophysiol. 2010 Apr 7;103(6):3274–3286. doi: 10.1152/jn.01043.2009

Table 1.

Summary of data used to determine differential sensitivities of the moist and dry cells in cockroaches and stick insects

Type of receptors Moist cell of cock-
roach
Dry cell of
cockroach
Moist cell of
stick insect
Dry cell of
stick insect

Stimulus: humidity
Range in which humidity oscillated, % RH 0 to 50 0 to 50 0 to 50 0 to 50
Range of the rate of humidity change, % RH s−1 −2 to +2 −2 to +2 −2 to +2 −2 to +2
Units tested extensively 38 40 42 38
Units used for multiple regressions 20 20 20 20
Number of multiple regressions 62 66 58 60
Number of points per multiple regression < 175 < 175 < 175 < 175
Mean correlation coefficient, r 0.94 ± 0.19 0.93 ± 0.17 0.95 ± 0.18 0.96 ± 0.17
Mean differential sensitivity to instantaneous
  humidity, imp s−1 / % RH
+ 0.52 −0.60 +0.42 −0.31
Mean differential sensitivity to the rate of hu-
  midity change, imp s−1 / % RH s−1
+5.11 −4.62 +2.51 −2.41

Stimulus: pressure
Range in which pressure oscillated, mbar 5 to 45 5 to 45 5 to 45 5 to 45
Range of the rate of humidity change, mbar s−1 −10 to +10 −10 to +10 −10 to +10 −10 to +10
Units tested extensively 32 34 46 44
Units used for multiple regressions 20 20 20 20
Number of multiple regressions 60 60 68 68
Number of points per multiple regression < 80 < 80 < 80 < 80
Mean correlation coefficient, r 0.98 ± 0.09 0.98 ± 0.09 0.97 ± 0.12 0.98 ± 0.11
Mean differential sensitivity to instantaneous
  humidity, imp s−1 / mbar
+0.14 −0.16 +0.77 −0.45
Mean differential sensitivity to the rate of hu-
  midity change, imp s−1 / mbar s−1
+0.15 −0.18 +0.52 −0.38