Skip to main content
. 2011 Sep 8;286(44):37990–37999. doi: 10.1074/jbc.M111.258012

TABLE 2.

Charge-switch mutations altered burst open probability and amplitude of single channel current amplitudes

Single channel recordings were gathered from outside-out patches held at −80 mV in extracellular saline containing 3 mm GABA; means are depicted ±95% confidence interval of fit. Some values were not determined (ND) for both mutants.

Measurement WT K328E K378E
Unitary current (pA) −2.03 ± 0.007 −1.97 ± 0.029 −1.37 ± 0.057a
Burst Popen 0.79 ± 0.017 0.86 ± 0.003 0.75 ± 0.006
Chord conductance (picosiemens) 26.1 ± 5.09 ND 17.2 ± 5.82
Reversal Potential (mV) −1.20 ± 10.2 ND −7.45 ± 19.4

a Mutants were compared to WT by the Student's t test with significance held at p < 0.05, n = 3.