Skip to main content
. 2011 Jun 21;469(12):3300–3306. doi: 10.1007/s11999-011-1949-0

Table 4.

Summary of complications related to the use of proximal humerus locking plates

Study Number of fractures Intra-articular screw penetration Screw cutout Loss of reduction Osteonecrosis
Agudelo et al. [1] 153 0% 4% 13.6% 4.5%
Brunner et al. [4] 158 14% 8% 5.7% 8%
Frankhauser et al. [8] 28 NR 18% 11% 7%
Lee and Shin [18] 45 NR 4% 11% 2.2%
Owsley and Gorczyca [23] 53 NR 23% 25% 4%
Neviaser et al. 38 0% 0% 2.6% 2.6%

NR = not clearly reported.