Skip to main content
. 2011 May 5;2011:1901.
Ref (type) Population Outcome, Interventions Results and statistical analysis Effect size Favours
Prevention of pressure ulcers

Systematic review
1606 people
10 RCTs in this analysis
Rate of pressure ulcer formation
with alternating-pressure surfaces
with constant-low-pressure supports
Absolute results not reported

RR 0.85
95% CI 0.64 to 1.13
P = 0.28
The meta-analysis pooled trials of several different types of surface and remains underpowered (the wide confidence intervals do not exclude a clinically important treatment effect). The review emphasised that many of the RCTs were small. It reported that further trials are needed to determine whether alternating-pressure devices and constant-low-pressure devices are associated with a clinically important difference in the risk of pressure ulceration
Not significant