Skip to main content
. 2011 Nov 3;7:67. doi: 10.1186/1746-6148-7-67

Table 2.

LAMP diagnosis of eimerian infection from field samples compared with lesion scoring and multiplex PCR.

Pen no. Lesion score1 (species) PCR2 LAMP



Duodenum Mid-intestine Caecae Duodenum Mid-intestine Caecae Duodenum Mid-intestine Caecae
1 - - - - - - - - -
2 1 (Eac) - - Eac - - Eac - -
3 - - - - - - - - -
4 - - - - - - - - -
5 - - - - - - - Ema -
6 - - - - - - - - -
7 1 (Eac) - - Eac - - Eac - -
8 - - - - - - - - -
9 1 (Eac) 2 (Ema) - Eac Ema - Eac Ema -
10 - 1 (Ema) - - Ema - - Ema -

Underlined entries were only detected using LAMP.

1Lesion scoring performed as described by Johnson and Reid [8]. 2Multiplex PCR performed as described by Fernandez et al [30].