Table 3.

Final release amount and time required achieving 50% release of various devices and parameters used for model fit in Figs. 3-5

Sample types * Final release Time to 50% release Model parameters
ks (hr-1) koff (hr-1) ΔG (10-21J)
E 84.0 ± 2.6% 10 h 0.080 0.0030 5.4
M 71.2 ± 3.2% 15 h 0.050 0.0033 2.5
DE 85.2 ± 4.3% 22 h 0.034 0.0010 7.4
EE 73.0 ± 1.9% 18 h 0.040 0.0010 4.0
ME 66.3 ± 1.7% 20.5 h 0.040 0.0015 2.2
DM 73.9 ± 4.4% 31.5 h 0.028 0.0018 3.5
EM 69.8 ± 2.0% 48 h 0.015 0.0020 3.0
MM 56.4 ± 4.3% 46 h 0.018 0.0010 0.5
*

E: EtOH-treated drug-loaded film without coating; M: MeOH-treated drug-loaded film without coating; DE: Originally non-treated drug-loaded core film with EtOH-treated SELP-47K coating; EE: Originally EtOH-treated drug-loaded core film with EtOH-treated SELP-47K coating; ME: Originally MeOH-treated drug-loaded core film with EtOH-treated SELP-47K coating; DM: Originally non-treated drug-loaded core film with MeOH-treated SELP-47K coating; EM: Originally EtOH-treated drug-loaded core film with MeOH-treated SELP-47K coating; MM: Originally MeOH-treated drug-loaded core film with MeOH-treated SELP-47K coating.